Blog Posts

Get Updated 200-355 Cisco CCNA Wireless Exam Preparation Questions

Posted by morgen root on November 19, 2018 at 7:11am 0 Comments

Pass Cisco 200-355 Dumps Questions Easily - Quick Tips To Pass

Are you familiar with the fact the Cisco has recently updated material of 200-355 Dumps Questions. Following the routine, Certificationssoul.com has also updated the material based on recommended material. Just to offer you an immediate answer against your challenges which you might face in 200-355 Exam. The new syllabus of 200-355 Cisco Certified Network Associate Wireless Practice Exam Questions is intended to validate…

Continue

1-diphosphonic acid in recycle-cooling water by ion chromatography

1-diphosphonic acid in recycle-cooling water by ion chromatography

1-Hydroxyethylidene-1,1-diphosphonic acid hedp 60) is usually used as a scale and corrosion inhibitor in recycle-cooling water for steel industry. The quick and accurate analysis of HEDP concentration in water is of importance to control the inhibitor adding program. However, the common method for HEDP analysis, which determines the total phosphate in water samples, may suffer the serious problem of incorrectly including degraded HEDP as the active HEDP reagent. In this study, the method of the determination of HEDP in recycle-cooling water by ion chromatography was investigated. The chromatographic parameters, including elution and detection, were optimized. The separation was achieved on an IonPac AS14A column with NaOH solution of 80 mmol/L as the eluent at a flow rate of 1. 0 mL/min, and the detection was performed by a suppressed conductivity detection mode with the injection volume of 25 microL. The method showed good linearity within the range of 0. 25 and 25 mg/L with an average recovery of 102%. The detection limit of the method reached as low as 0. 1 mg/L. The relative standard deviations for 0. 25 and 0. 5 mg/L HEDP standard solutions were 4. 7% and 3. 5% (n = 13) , respectively. The method has been applied for the determination of hedp phosphonate in recycle-cooling water samples with the advantages of being simple, fast, sensitive, and interference free.

Determination of 1-hydroxyethylidene-1, 1-diphosphonic acid in recycle-cooling water by ion chromatography | Request PDF. Available from:

Views: 1

Comment

You need to be a member of On Feet Nation to add comments!

Join On Feet Nation

© 2018   Created by PH the vintage.   Powered by

Badges  |  Report an Issue  |  Terms of Service