Language: English

 


 


 

 

 

 

 

 

 


 


 


 


 


 


 


 


 


 


 


 


 


 


 


 


 


 

VA Standard Internal Batteries 1 EBM 2 EBMs 3 EBMs 4 EBMs Tower Models 1000 5/14 25/60 55/170 83/199 109/228 1500 6/17 33/79 63/146 92/174 120/201 2200 5/14 26/60 55/170 81/198 106/224 Two-in-One Form Factor 1000 7/19 33/68 58/120 82/166 105/214 1500 5/13 23/57 49/161 73/172 96/205 2400 7/19 35/73 60/124 85/177 110/229 3000 5/15 25/61 49/103 69/146 90/190.
*Up to 4 EBMs can be connected to 1000-3000VA models. EBM run times include internal batteries. Run time chart provides typical information. Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Eaton 5125 Battery Run Time Chart (in minutes full load/half load)*

Model Number 1 Power Rating (VA/Watt) Input/ Output Voltage (Vac) 2 Input Connection Output Receptacles 4 Dimensions HxWxD (in/mm) Weight (lb/kg) Tower Models (North America) PW5125 1000 1000/700 120 5-15P, 6 ft line cord (6) 5-15R 9.45 x 6.38 x 15.79/ 240 x 162 x 401 34.3/15.6 PW5125 1500 1440/1050 120 5-15P, 6 ft line cord (6) 5-15R 9.84 x 6.38 x 18.39/ 250 x 162 x 467 50.7/23.0 PW5125 2200 1920/1600 120 5-20P, 6 ft line cord (6) 5-15R, (2) 5-20R 9.84 x 8.07 x 19.41/ 250 x 205 x 493 68.3/31.0 PW5125 2200b 2080/1600 208 IEC-320-15A, inlet 3 (9) IEC-320-10A (C13) 9.84 x 8.07 x 19.41/ 250 x 205 x 493 68.3/31.0 Tower Models (International) PW5125 1000i 1000/700 230 IEC-320-10A, inlet 3 (6) IEC-320-10A (C13) 9.45 x 6.38 x 15.79/ 240 x 162 x 401 34.3/15.6 PW5125 1500i 1500/1050 230 IEC-320-10A, inlet 3 (6) IEC-320-10A (C13) 9.84 x 6.38 x 18.39/ 250 x 162 x 467 50.7/23.0 PW5125 2200i 2200/1600 230 IEC-320-10A, inlet 3 (9) IEC-320-10A (C13) 9.84 x 8.07 x 19.41/ 250 x 205 x 493 68.3/31.0 Two-in-One Form Factor Models 5 (North America) PW5125 1000 RM 1000/900 120 5-15P, 6 ft line cord (6) 5-15R 3.5 x 17.0 x 19.4/ 89 x 432 x 494 61.0/27.67 PW5125 1500 RM 1440/1340 120 5-15P, 6 ft line cord (6) 5-15R 3.5 x 17.0 x 19.4/ 89 x 432 x 494 61.0/27.67 PW5125 2400 RM 2400/2250 120 L5-30P, (12' attached) (1) L5-30R, (6) 5-15R 3.5 x 19.0 x 24.5/ 89 x 482.6 x 622.3 89.0/40.40 PW5125 3000 RM 2880/2700 120 L5-30P, (12' attached) (1) L5-30R, (6) 5-15R 3.5 x 19.0 x 24.5/ 89 x 482.6 x 622.3 89.0/40.40 Two-in-One Form Factor Models 5 (International) PW5125 1000i RM 1000/900 230 IEC-320-10A, inlet 3 (6) IEC-320-10A (C13) 3.5 x 17.0 x 19.4/ 89 x 432 x 494 61.0/27.67 PW5125 1500i RM 1500/1340 230 IEC-320-10A, inlet 3 (6) IEC-320-10A (C13) 3.5 x 17.0 x 19.4/ 89 x 432 x 494 61.0/27.67 PW5125 2400i RM 2400/2250 230 IEC-309 16A P, (12' attached) (1) IEC-320-16A (C19) (9) IEC-320-10A (C13) 3.5 x 19.0 x 24.5/ 89 x 482.6 x 622.3 89.0/40.40 PW5125 3000g RM 6 3000/2700 200-240 IEC-320-16A, receptable (1) IEC-320-16A (C19) (9) IEC-320-10A (C13) 3.5 x 19.0 x 24.5/ 89 x 482.6 x 622.3 89.0/40.40 PW5125 3000e RM 7 3000/2700 230 IEC-320-16A, receptacle (1) IEC-320-16A (C19) (9) IEC-320-10A (C13) 3.5 x 19.0 x 24.5/ 89 x 482.6 x 622.3 89.0/40.40 PW5125 3000i RM 8 3000/2700 230 IEC-309 16A P, (12' attached) (1) IEC-320-16A (C19) (9) IEC-320-10A (C13) 3.5 x 19.0 x 24.5/ 89 x 482.6 x 622.3 89.0/40.40 PW5125 3000j RM 9 2400/2250 100 L5-30P (12' attached) (1) L5-30R (6) 5-15R 3.5 x 19.0 x 24.5/ 89 x 482.6 x 622.3 89.0/40.40.
Eaton 5125 RM UPS - Especificaciones TГ©cnicas modelo Americano (Low Voltage)
Model Selection Guide.
Electrical Input 1000-2200 VA 2400-3000 VA Nominal Voltage 120, 208 and 230 Vac; See Model Selection Guide for user-selectable volages 120, 208, 230 and 240Vac; See Model Selection Guide for user-selectable volages Input Voltage Ranges (for user-selectable voltages) Low voltage: 77-152V; High voltage: 154-288V Operating Frequency 50/60Hz, Auto-sensing Frequency Range 46-65Hz Electrical Output On Utility Voltage Regulation -10% to +6% of nominal On Battery Voltage Regulation В±5% RMS Voltage Wave Shape (on battery) Sine Wave Output Protection Short circuit protection Battery Battery Type Sealed, lead-acid; maintenance free Battery Run time See Battery Run Times Table Battery Replacement Hot-swappable internal batteries and external batteries modules Recharge Time.
1. 50/60 automatic frequency selection. 2. 120 V models are 110 V,120 V,127 V user-selectable.230 V models are 220 V,230 V,240 V user-selectable.208 V models are 208 V,220 V,230 V,240 V user-selectable. 3. Includes(2) each IEC interconnect cables. 4. 1000-1500VA models divided into (2) Load Segments (receptacle groups). 2200-3000VA models are divided into (3) Load Segments (receptacle groups). 5. Unit fits in standard 19-inch racks. Mounting kits are sold separately. 6. g-model carries agency listing cUL; C-Tick; TUV/GS; CE. 7. e-model carries agency listing CE mark only. 8. i-indicating international model, 230 V. 9. j -indicating Japanese model, 100 V.