Eaton 5125 Battery Run Time Chart (in minutes full load/half load)*
*Up to 4 EBMs can be connected to 1000-2200 VA models. EBM run times include internal batteries. Run time chart provides typical information. Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Model Number 1 Power Rating (VA/Watt) Input/ Output Voltage (Vac) 2 Input Connection Output Receptacles 4 Dimensions HxWxD (in/mm) Weight (lb/kg) Tower Models (North America) PW5125 1000 1000/700 120 5-15P, 6 ft line cord (6) 5-15R 9.81 x 6.38 x 15.79/ 249 x 162 x 401 34.3/15.6 PW5125 1500 1440/1050 120 5-15P, 6 ft line cord (6) 5-15R 9.81 x 6.38 x 18.39/ 249 x 162 x 467 50.7/23.0 PW5125 2200 1920/1600 120 5-20P, 6 ft line cord (6) 5-15R, (2) 5-20R 9.84 x 8.07 x 19.41/ 250 x 205 x 493 68.3/31.0 PW5125 2200b 2080/1600 208 IEC-320-15A, inlet 3 (9) IEC-320-10A (C13) 9.84 x 8.07 x 19.41/ 250 x 205 x 493 68.3/31.0 Tower Models (International) PW5125 1000i 1000/700 230 IEC-320-10A, inlet 3 (6) IEC-320-10A (C13) 9.81 x 6.38 x 15.79/ 249 x 162 x 401 34.3/15.6 PW5125 1500i 1500/1050 230 IEC-320-10A, inlet 3 (6) IEC-320-10A (C13) 9.81 x 6.38 x 18.39/ 249 x 162 x 467 50.7/23.0 PW5125 2200i 2200/1600 230 IEC-320-10A, inlet 3 (9) IEC-320-10A (C13) 9.84 x 8.07 x 19.41/ 250 x 205 x 493 68.3/31.0.
VA Standard Internal Batteries 1 EBM 2 EBMs 3 EBMs 4 EBMs Tower Models 1000 5/14 25/60 55/170 83/199 109/228 1500 6/17 33/79 63/146 92/174 120/201 2200 5/14 26/60 55/170 81/198 106/224.
1. 50/60 automatic frequency selection. 2. 120 V models are 110 V, 120 V, 127 V user-selectable. 230 V models are 220 V, 230 V, 240 V user-selectable. 208 V models are 208 V, 220 V, 230 V, 240 V user-selectable. 3. Includes (2) each IEC interconnect cables. 4. 1000-1500 VA models are divided into (2) Load Segments (receptacle groups). 2200-3000 VA models are divided into (3) Load Segments (receptacle groups). 5000/6000VA models are divided into (2) Load Segments.
Model Selection Guide.
Eaton 5125 UPS Technical Specs (International)

Electrical Input 1000-2200 VA Nominal Voltage 120, 208 and 230 Vac; See Model Selection Guide for user-selectable voltages Input Voltage Ranges (for user-selectable voltages) Low voltage: 77-152 V; High voltage: 154-288 V Operating Frequency 50/60 Hz, Auto-sensing Frequency Range 46-65 Hz Electrical Output On Utility Voltage Regulation -10% to +6% of nominal On Battery Voltage Regulation В±5% RMS Voltage Wave Shape (on battery) Sine Wave Output Protection Short circuit protection Battery Battery Type Sealed, lead-acid; maintenance free Battery Run time See Battery Run Times Table Battery Replacement Hot-swappable internal batteries and external batteries modules Recharge Time.