General Specifications - Yokogawa.
General Specifications GS 33Y05Q10-32E.
Models SSS7700, SSS7710, SSS7711, SSS7720, SSS7750 Plant Resource Manager.
 GENERAL Plant Resource Manager (PRM®) is an asset management software tool for the digital network era. The PRM software manages field devices and maintenance work efficiently, and help reduce total cost of ownership (TCO) in an industrial plant. These packages support intelligent devices such as Foundation™ fieldbus, HART, PROFIBUS, and ISA100.11a field wireless devices as well as conventional analog devices.
 PRODUCT OVERVIEW Plant Resource Manager (PRM) consists of the following components:
l PRM Server • Collects and stores maintenance related data such as device parameters, device alarms, and inspection memo in the field. • Generates and manages centralized device information such as device lists, inspection schedules and records, user-created electronic documents, and parts lists. • Generates maintenance alarms for field device maintenance with action guidance information (problem, cause, and action) and notifies these alarms to the people who need them.
l PRM Client • Provides device navigator windows in hierarchy tree view for monitoring and managing devices. • Performs automatic device recognition and registration (plug & play) by using full digital, bi-directional, field digital networks such as Foundation fieldbus, HART, PROFIBUS, and ISA100.11a. Monitors device health status with maintenance alarms and communication errors. With PRM Advanced Diagnostic Function, PRM also performs device status diagnosis, device parameter setting using device diagnostic tools (i.e. DeviceViewer, DTM Works, DD menu). • Displays status icons reflecting the communication and device status to let operators grasp the device status intuitively. A confirmation status icon appears for the devices with unacknowledged maintenance alarms (of the device health status). • A status signal of a field device complying with NAMUR NE107 specifications is displayed on the Signal View of the Device Navigator. NE107 is a recommendation for self-monitoring and diagnosis of field devices published by NAMUR, an international user association of automation technology in process industries headquartered in Germany. • Device icons to be displayed on the device navigator can freely be defined by a user. The user can customize those fonts and icons depending on the user requirements and the screen size. • Maintenance marks are a kind of flags to be assigned to devices for setting and checking maintenance status. The maintenance mark icon is displayed upon setting, and enables to temporarily change device access level. The maintenance marks can also be linked with CENTUM’s operation marks so that the maintenance engineers and operators can share the same information and coordinate their work. • Performs online device adjustment/setting on screen using the same user interface with FieldMate versatile device management tool which is an on-site device adjustment/setting tool. • Possible to exchange parameters and maintenance information between PRM and FieldMate. • Provides PRM advanced diagnosis application, device diagnosis data historian, and general-purpose diagnosis tool for PRM advanced diagnosis function, in addition to the maintenance alarm function and device diagnostics function. • Allows registering conventional analog field devices as well as field digital devices such as Foundation fieldbus, HART, PROFIBUS, and ISA100.11a, for a true, centralized device management. • Implements third-party calibration and diagnostic software tools as PLUG-IN applications. DeviceViewer (*1) and PLUG-IN ValveNavi are available from Yokogawa brand. • Supports FDT/DTM (Field Device Tool/Device Type Manager) and EDDL (Electronic Device Description Language) technologies that enable PRM interfacing with field devices. *1:
DeviceViewer is a PLUG-IN application of the PRM Client for self-diagnosis of field digital devices such as Foundation fieldbus and HART. A field device information and its status signal complying with NAMUR NE107 are displayed on the DeviceViewer. Download device definition files from each device vendor to run on the DeviceViewer prior to its use. DeviceViewer can be displayed on CENTUM VP/CS 3000 (R3.07 or later) HIS with operation and monitoring functions.
Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802.
GS 33Y05Q10-32E ©Copyright Jul. 26, 2006(YK) 15th Edition May 28, 2014(YK)
l Field Communications Server This is a server to set and acquire field device data online. It implements data exchange between the field devices and the PRM Client or the PRM Server. Those data are distributed among maintenance support applications such as device status monitoring, device parameter tuning, and device diagnostics. PRM supports various types of field communication protocols (Foundation fieldbus, HART, PROFIBUS, and ISA100.11a) and the following system configuration types are available. Supported hardware • Foundation fieldbus Communication Modules for CENTUM VP/CS 3000 • AI/AO modules with HART communication for CENTUM VP/CS 3000 • PROFIBUS Communication Module for CENTUM VP/CS 3000 • Foundation fieldbus Communication Modules for STARDOM • AI/AO modules with HART communication for STARDOM • PROFIBUS Communication Module for STARDOM • AI/AO modules with HART communication for ProSafe-RS • NI-FBUS card • 3rd party HART multiplexers (Pepper and Fuchs, MTL, ELCON, and STAHL) • 3rd party PROFIBUS communication devices (CommunicationDTM/GatewayDTM communications) • Field Wireless Access Point and Field Wireless Management Station (CommunicationDTM/GatewayDTM communications)
l Multiple Server Switchover PRM manages CENTUM VP/CS 3000, ProSafe-RS, or STARDOM projects. It also provides an integrated monitoring for a large-scale project which is geographically distributed in remote locations. In case for the large-scale project where tens of thousands of field devices are installed, it is necessary to divide them into multiple numbers of PRM Servers. PRM’s Multiple Server Function enables to select which PRM Server the PRM Client refers to. In this way, a single PRM Client is able to monitor several PRM Servers.
l PRM Advanced Diagnosis Server Function (optional) This sever function provides an environment for executing diagnostic algorithms by utilizing field device parameters. The diagnostic algorithm application can be configured by using the PRM Advanced Diagnostic Software Development Kit (PAA-Development Kit) without any additional software program. By monitoring parameters and process data transmitted from field devices, the PRM Advanced Diagnosis Server Function configures and executes diagnosis of the devices and assets. For details of the PRM Advanced Diagnosis Server Function, refer to general specifications of SSS7740 PRM Advanced Diagnosis Server (GS 33Y05Q21-32E).
 PST Scheduler Package (optional) PST(*1) stands for a partial stroke test. The PST Scheduler schedules PST, automatically executes PST in accordance with the schedule, and manages the results in unified manners. It is possible to modify the planned schedules and switch PST execution from automatic to manual. For details of the PST Scheduler Package, refer to general specifications of SSS7780 PST Scheduler Package (GS 33Y05Q23-32E). *1:
By slightly operating emergency shutdown (ESD) valves online which are not activated under normal conditions, PST is to check if ESD valves function correctly in case of emergency. By using PST, the interval period between full stroke tests can be prolonged without disturbing the safety of the ESD valves, thus the maintenance cost for those ESD valves can be reduced.
l Interface for Computerized Maintenance Management System (optional) PRM has an interface with Maximo, a Computerized Maintenance Management System (CMMS), from IBM Software, Inc. It enables PRM to provide maintenance information to the maintenance management system online. For details of the CMMS interface, refer to general specifications of SSS7730 Interface for CMMS (GS 33Y05Q20-32E).
l Interface for GE Energy’s System 1® (optional) PRM is able to provide a single monitoring window for diagnosis of turbines, rotating equipment and reciprocating equipment under management by GE Energy’s System 1 Optimization and Diagnostics Software Platform in addition to field devices such as pressure transmitters and flowmeters. For details of System 1 integration, refer to general specifications of SSS7770 Interface for GE Energy’s System 1 (GS 33Y05Q22-32E).
All Rights Reserved. Copyright © 2006, Yokogawa Electric Corporation.
GS 33Y05Q10-32E May 28, 2014-00.
PRM manages a PRM Server as one unit. The PRM system can be configurable in scalable ways – a minimum system consists of a PRM Server, Field Communications Server and a PRM Client all resided in a single computer, and a large system with multiple clients. Examples of PRM system configurations are shown in this section.
l System configuration CENTUM VP/CS 3000 PRM Client.

http://tersekosco1985.eklablog.com/abit-bf6-bios-download-working-a...